Skip to content
‹ Wood-Burning Sauna Stoves
1 / 4

Harvia Legend Wood-Burning Sauna Stove

From $2,089

Available to order

Power (kW): 16kW (Legend 150)

Get the complete kit instead from $6,794

Not sure which size or heater? Talk it through with a sauna advisor.

Key details

  • Indoor placement
  • Power: 15.9–23.5 kW
  • Wood-burning heater
  • Three sizes - Legend 150 (~16 kW, small-medium rooms), Legend 240 (medium), and Legend 300 (~23.5 kW, large rooms)
  • Cast-iron GreenFlame glass door - watch the fire while you bathe
  • Large stone capacity for soft, steady heat at lower temperatures

Overview

The Harvia Legend is a floor-standing wood-burning sauna stove built around a round black steel frame that holds a large load of stones around the fire chamber. As the stones heat up they give a full sauna bath even at a lower room temperature, and they keep the heat going if the fire dies down between loads.

Three sizes are offered. The Legend 150 is rated 16 kW for rooms of 212 to 459 cu ft, the Legend 240 is rated 21 kW for 353 to 848 cu ft, and the Legend 300 is rated 23 kW for 494 to 989 cu ft.

There is nothing to wire and no control panel. Heat is set by the fire itself and by how far the ash box is opened, which regulates the draught. The grate sends part of the combustion air to the upper fire chamber so the flue gases also burn, for a cleaner and more controlled burn.

Side and rear clearances to combustible walls are smaller than usual for a wood stove, so benches can be placed more freely. The stove connects to a flue through its rear or top opening and can be fitted with Harvia's pipe-mounted water heater.

Highlights

  • Three sizes - Legend 150 (~16 kW, small-medium rooms), Legend 240 (medium), and Legend 300 (~23.5 kW, large rooms)
  • Cast-iron GreenFlame glass door - watch the fire while you bathe
  • Large stone capacity for soft, steady heat at lower temperatures
  • Clean-burn grate directs combustion air for efficient, low-smoke burning
  • Heavy black-steel construction; floor-standing; no electricity required
  • The 300 takes longer firewood (up to ~18.5")
Harvia Legend Wood-Burning Sauna Stove
Harvia Legend Wood-Burning Sauna Stove

Key features

  • Large stone mass

    Up to 264.6 lb on the Legend 150, 441 lb on the Legend 240 and 573.3 lb on the Legend 300, for soft, steady heat that holds even as the fire burns down.

  • Air-splitting grate

    Combustion air channels lead part of the air above the fire to the upper fire chamber, so the flue gases burn and add heat. Harvia says the grate design also lengthens the stove's life.

  • Glass door

    The Legend 150 and 240 have a cast-iron glass door and the Legend 300 a large steel-framed glass door, so the fire is visible from the benches. The door opening direction can be changed.

  • Smaller clearances

    Only 7.87 in to combustible materials at each side and 9.84 in behind, which leaves more freedom in bench layout.

  • Adjustable legs

    Legs adjust by up to 1.2 in (30 mm) to level the stove and set the height of the flue connection.

  • Rear or top flue connection

    A 4.5 in (115 mm) connection opening on the back or top suits a masonry flue or the Harvia steel chimney WHP1500.

  • Water heater ready

    Harvia's VL22 pipe-mounted water heater fits on the upper connection opening. On the Legend 240 and 300 the WZ020ST connecting pipe lifts it to the right height.

  • Tested to EN 15821

    All three sizes are type-tested to EN 15821:2010, the European standard for wood-fired sauna stoves, with test results published in Harvia's declaration of performance.

Specifications

SKUWK150LD
Harvia modelLegend 150: WK150LD; Legend 240: WK240LD; Legend 300: WK300LD
Heat outputLegend 150: 16 kW; Legend 240: 21 kW; Legend 300: 23 kW
Room sizeLegend 150: 212 to 459 cu ft (6 to 13 m³); Legend 240: 353 to 848 cu ft (10 to 24 m³); Legend 300: 494 to 989 cu ft (14 to 28 m³)
Fuel and powerWood only; no electrical connection
Stone capacityLegend 150: 264.6 lb (120 kg); Legend 240: 441 lb (200 kg); Legend 300: 573.3 lb (260 kg); stones 4 to 6 in (10 to 15 cm)
Dimensions (H x W x D)Legend 150: 29.13 x 20.87 x 20.87 in (740 x 530 x 530 mm); Legend 240: 32.68 x 23.62 x 23.62 in (830 x 600 x 600 mm); Legend 300: 40.94 x 23.62 x 25.98 in (1040 x 600 x 660 mm); legs add 0 to 1.2 in (0 to 30 mm)
Net weight (without stones)Legend 150: 135.6 lb (61.5 kg); Legend 240: 167.8 lb (76.1 kg); Legend 300: 201.5 lb (91.4 kg)
Flue connectionBack or top, 4.5 in (115 mm) opening; minimum flue pipe inside diameter 4.3 in (110 mm); chimney temperature class T600
FirewoodMaximum length: Legend 150: 13.8 in (35 cm); Legend 240: 15.4 in (39 cm). Diameter 3.1 to 5.9 in (8 to 15 cm) for all sizes
Wood per load (ignition / refuelling)Legend 150: 6.0 / 7.1 lb (2.7 / 3.2 kg); Legend 240: 6.4 / 11.5 lb (2.9 / 5.2 kg); Legend 300: 6.6 / 13.2 lb (3.0 / 6.0 kg)
Total efficiencyLegend 150: 67%; Legend 240: 67%; Legend 300: 68%
Fire chamber top thicknessLegend 150: 0.2 in (5 mm); Legend 240: 0.39 in (10 mm); Legend 300: 0.24 in (6 mm)
Clearance to combustibles, frontLegend 150: 19.69 in (500 mm); Legend 240: 24.8 in (630 mm); Legend 300: 26.77 in (680 mm)
Clearance to combustibles, sides and rearAll sizes: 7.87 in (200 mm) each side; 9.84 in (250 mm) behind
Clearance to ceilingAll sizes: 39.4 in (1000 mm)
Clearance to non-combustible wallsAll sizes: 3.94 in (100 mm) at sides and rear
Smoke pipe clearance19.7 in (500 mm) to combustible materials for an unprotected smoke pipe; 9.8 in (250 mm) with Harvia radiation cover WZ020130
FloorUntiled concrete at least 2.4 in (60 mm) thick needs no extra protection; tiled or combustible floors need Harvia protective bedding WL100 or similar heat protection
Water heater optionHarvia VL22 pipe-mounted water heater on the upper connection opening; Legend 240 and 300 also need connecting pipe WZ020ST
Material and finishBlack steel frame and steel stove body
CertificationsType-tested to EN 15821:2010 (notified body VTT, 0809); CE and EAC marked (Legend 150 and 240 as listed by Harvia)
BrandHarvia
Product typeSauna Heater
PlacementIndoor
Power15.9–23.5 kW
Heater typeWood-burning

What's included

  • Harvia Legend wood-burning sauna stove with GreenFlame glass door
  • Installation and operation manual

FAQ

Which Legend size is right for my sauna?

Match the room volume: Legend 150 for 212 to 459 cu ft, Legend 240 for 353 to 848 cu ft, Legend 300 for 494 to 989 cu ft. Harvia adds about 42 cu ft (1.2 m³) for every 10.8 sq ft (1 m²) of uninsulated brick, glass, tile or concrete surface, and multiplies the volume by 1.5 for solid log walls. A stove that is too small has to be fired harder and longer, which shortens its life.

Does it need electricity or a control unit?

No. The Legend is heated with wood only and has no electrical connection. You regulate the burn by opening or closing the ash box; the stove is not meant to be used with the fire door open.

How many stones does it take, and which kind?

Up to 264.6 lb (120 kg) on the Legend 150, 441 lb (200 kg) on the 240 and 573.3 lb (260 kg) on the 300, sized 4 to 6 in (10 to 15 cm). Harvia lists peridotite, olivine diabase, olivine and vulcanite as suitable, and the stove body must be fully covered with stones, since exposed areas can overheat nearby structures.

What chimney or flue does it connect to?

The stove has a 4.5 in (115 mm) connection opening on the back and on top. It can go to a masonry flue with a minimum inside diameter of 4.3 in (110 mm), class T600, or to the Harvia steel chimney WHP1500. It is not suitable for a shared flue system.

How close can my benches and walls be?

To combustible materials: 7.87 in at each side, 9.84 in behind, 39.4 in to the ceiling, and at the front 19.69 in (Legend 150), 24.8 in (240) or 26.77 in (300). To non-combustible walls Harvia lists 3.94 in.

Can the Legend heat bathing water?

Yes, with Harvia's VL22 pipe-mounted water heater installed on the upper connection opening. The Legend 240 and 300 also need the WZ020ST connecting pipe to lift the water heater to the right level.

Can I feed the fire from outside the sauna room?

Harvia makes separate SL versions of the Legend 150 and 240 (WK150LDSL and WK240LDSL) with a fire chamber extension that passes through the wall. The three stoves listed here load from inside the sauna.

Is the Legend UL listed for North America?

Harvia's documents list EN 15821:2010 type testing and CE and EAC marking; they do not state a UL or ULC listing. The manual says all local regulations must be followed and that local fire authorities can advise on approval.

Can I order it online?

Yes. Add it to your cart and pay through secure checkout by Stripe.

You may also need

Compare similar

Specifications from harvia.com and pim.harvia.com.

1 / 4

Harvia Legend wood-burning sauna stove